HSM3105 is designed to manage a maximum allowable current consumption in the MX loop of 400 mA @ 40 V (equivalent to 1600 mA @ 11.3 V or 1500 mA @ 12.5 V). Please note that HSM2300 and HSM2204 can only supply up to 228 mA @ 40 V (1000 mA @ 12.5 V) or 260 mA @ 40 V (1000 mA @ 11.3 V).
- Maximum 126 devices
- Corbus wire distance 3 Ft Max between panel and module (22AWG wire)
- ROHS Compliant
- Inputs for connecting a tamper switch when installed in a separate enclosure (required for UL/ULC).
- Support for two and four wire configurations
- Support for T-Tapping/Spurs
- IQ Pro Compatible
- Can be installed inside the IQ Pro enclosure or separate
- High and Low Power Modes
- Install with IQ Installer
- Load configuration using a linked spreadsheet
- Compatible enclosures: HSC3010C, HSC3010CR, HSC3030CAR, HSC3020C, HSC3001C, HSC3001CP, HSC3020CP, PC4050CAR, PC4050CR, PC5003C
Compatible devices: MX945, MX916, MX862, MC920, MX922, MX926, MX936, MX975, MX974, MXBAS
Note: For the MX920 device, the alarm current (16mA) is due to a loop fault. This fault occurs when the isolator is tripped. (loop in short circuit condition)
Technical Specifications:
- Manufacturer DSC
- Board current consumption 100 mA (without devices on MX loop) + MX loop current consumption (depending on the connected loop devices)
- Input power 11.3 to 12.5 VDC / 350 mA to 325 mA (supplied by alarm controller)
- Operating temperature -10C to 55C
- Corbus cable distance 0.9 m maximum between panel and module
- Board dimensions 83 x 145 mm